What this topic covers
MWA E, Fluid Power Systems, as numbered in the 2017 RSOS: hydraulic systems (task E-21; E-23 in the 2026 RSOS) and pneumatic and vacuum systems (E-22; E-24). Circuit symbols are described in words. These are original practice notes, not official material of the Red Seal Program or ESDC. Safety points are principles common to all provinces; a provincial rule is always given with its province. For settings, clearances, torques and temperatures, follow the manufacturer's specifications.
Hydraulic principles and components
- Pascal's law: pressure on a confined fluid is transmitted undiminished and equally in all directions (sub-task E-21.01).
- Variable displacement: an axial piston pump with a tilting swashplate; gear, gerotor and balanced vane pumps are fixed (sub-task E-21.02).
- Sequence valve: closed until its set pressure, then feeds the next actuator; a relief valve sends oil to tank, a reducing valve limits downstream pressure (sub-task E-21.02).
- DCV centres: closed = all ports blocked; open = all joined; tandem = work ports blocked, pump to tank; float = work ports to tank (sub-task E-21.02).
- Reservoir: return line below the oil level and away from the suction line (sub-task E-21.01).
Hydraulic diagnosis
- Foamy oil, whining pump: aeration; check suction fittings, pump shaft seal and oil level (sub-task E-21.02).
- Heat: a fixed pump against a closed-centre valve dumps full flow over the relief valve, turning it into heat (sub-task E-21.02).
- Hot tank line at the relief valve: a poppet held off its seat by debris (sub-task E-21.02).
- Piston seal test: with the rod-end line removed, steady flow from that port shows worn piston seals (sub-task E-21.02).
- Cooler: hot oil with the relief valve closed: check cooler water flow and scale (sub-task E-21.03).
Hydraulic safety
- Hose leaks: check with cardboard, never by hand; an oil jet can pierce skin (sub-task E-21.03).
- Accumulators: pre-charge with dry nitrogen; never compressed air or oxygen (sub-task E-21.04).
Calculations
- Force: Formula 4 of the formula sheet, force = pressure × area, with Formula 3, area = π × radius² (sub-task E-22.02).
- Vacuum cup: 10 psi × π × 1.5² (7.07 in.²) = 71 lb. (sub-task E-22.02).
- Cylinder volume: Formula 14, height × π × radius²; ÷ 231 in.³/gal. gives gallons (sub-task E-21.04).
- Cylinder speed: flow ÷ area; 10 gpm × 231 = 2310 in.³/min ÷ 12.57 in.² = 184 in./min (sub-task E-21.02).
Pneumatic and vacuum systems
- FRL: filter, regulator, then lubricator; use the lubricator oil the manufacturer specifies (sub-task E-22.03).
- Aftercooler: cools discharge air so water condenses and is drained (sub-task E-22.03).
- Drains: drip leg and automatic drain at the low end of a sloped main (sub-task E-22.01).
- Receivers: a pressure vessel protected by a relief valve (sub-task E-22.01).
- Venturi generator: Bernoulli's principle, vacuum with no moving parts (sub-task E-22.01).
- Water at the tools: moisture not removed by the dryer or not drained (sub-task E-22.02).
- Cylinder speed control: metering the exhaust air keeps back pressure for steady motion (sub-task E-22.03).
- Valve 5/2: five ports, two positions (sub-task E-22.04).
- Compressed air: never at skin or to clean clothing; it can enter the bloodstream (sub-task E-22.04).
Sample questions (5)
1. According to Pascal's law, how is pressure applied to a confined fluid transmitted through that fluid?
- In a straight line along the applied force.
- Toward the end with the larger piston area.
- Equally in all directions within the fluid.
- Toward the outlet with the lowest pressure.
Pascal's law, one of the principles of fluid power listed in sub-task E-21.01 of the RSOS, states that pressure applied to a confined fluid is transmitted undiminished and equally in all directions. It does not travel in a straight line along the applied force, and it does not head for a low-pressure outlet, because a confined fluid at rest has the same pressure at every point. A larger piston area gives a larger force at the same pressure; it does not draw the pressure toward it.
2. In a hydraulic circuit, what causes pressure to build up in the fluid?
- The capacity of the oil reservoir tank.
- The rotating speed of the electric drive motor.
- Resistance to the flow coming from the pump.
- The total volume of oil held in the lines.
Sub-task E-21.02 of the RSOS lists the principles of fluid power. A pump only delivers flow; pressure builds when that flow meets resistance from a load, a restriction or a closed valve. Motor speed changes the flow rate, tank capacity affects cooling and settling, and line volume affects response, but none of them creates pressure by itself.
3. Which hydraulic pump can change its displacement by tilting a swashplate?
- Axial piston pump.
- Balanced vane pump.
- Internal gerotor pump.
- External gear pump.
An axial piston pump with a tilting swashplate changes the piston stroke and so the displacement, as described among the pumps of sub-task E-21.02 of the RSOS. External gear, gerotor and balanced vane pumps have a fixed displacement set by their geometry; they have no swashplate to tilt.
4. What is the main job of a pressure relief valve in a hydraulic circuit?
- Reduces the pressure in one branch circuit.
- Controls the travel speed of the actuator.
- Limits the maximum pressure in the system.
- Holds a vertical load against gravity.
A relief valve opens at its setting and passes pump flow to tank, which caps the system pressure checked and adjusted under sub-task E-21.03 of the RSOS. It does not set actuator speed, which is the job of a flow control valve. Reducing the pressure of one branch belongs to a pressure reducing valve, and holding a load belongs to a counterbalance valve.
5. Which gas is used to pre-charge a bladder-type accumulator?
- Shop compressed air.
- Dry nitrogen gas.
- Carbon dioxide gas.
- Pure oxygen gas.
Accumulators are pre-charged with dry nitrogen, an inert gas, following the manufacturer's procedure under sub-task E-21.04 of the RSOS. Compressed air or oxygen mixed with oil under pressure can ignite or explode, and shop air also brings moisture into the accumulator. Carbon dioxide is not used because it can liquefy at accumulator pressures and dissolve in the oil.