MWA F of the 2017 RSOS: preventative and predictive maintenance (task F-23; F-25 in the 2026 RSOS) and commissioning and decommissioning (task F-24; F-26). These are original practice notes, not material from the Red Seal Program or ESDC. Safety points are principles common to all provinces. For lubrication quantities, alarm limits and run-in periods, follow the manufacturer's specifications.
1. What is the main purpose of a CMMS in a maintenance department?
A computerized maintenance management system schedules PM tasks, issues work orders and keeps the equipment history that sub-task F-23.01 of the RSOS lists as a source of maintenance information. Vibration is measured with a data collector, speed is controlled by a drive, and internal flaws are found by NDT methods such as ultrasonic testing, not by software.
2. A millwright hears a new rattling noise from a pump bearing housing during a PM round. What is the correct next step?
Sub-task F-23.01 of the RSOS has the millwright record information for future evaluation and repair, so the finding is logged and a work order raised. Waiting for the next round leaves the defect unreported, extra grease can mask or worsen it, and replacing the bearing without diagnosis may fix nothing and wastes parts.
3. Which type of maintenance is performed at set time intervals regardless of equipment condition?
Preventative maintenance is scheduled by time or running hours, as listed among the types of maintenance in sub-task F-23.01 of the RSOS. Breakdown and corrective maintenance happen after a failure or defect appears, and predictive maintenance is triggered by measured condition rather than by the calendar.
4. On a scheduled lubrication route, what should be done first at a bearing grease fitting?
Sub-task F-23.01 of the RSOS has components lubricated to site and manufacturers' specifications, so the fitting is wiped first to keep dirt out of the bearing and the correct grease is confirmed. Removing the end cover to drain the grease or blowing it out with compressed air is not part of a routine greasing task, and pumping until grease flows from the seals over-greases the bearing, which can overheat it and damage the seals.
5. A fan shows a high vibration peak at 1x rpm in the radial direction, with low axial vibration. What is the most likely cause?
A strong radial peak at 1x rpm with little axial vibration is the signature of imbalance, one of the causes of vibration named in sub-task F-23.02 of the RSOS. Angular misalignment shows high axial vibration at 1x and 2x, looseness produces many harmonics, and a race defect appears at non-synchronous bearing frequencies.