What this topic covers
MWA D of the 2017 RSOS: robotics and automated equipment (task D-15; D-17 in the 2026 RSOS), fans and blowers (D-16; D-18), pumps (D-17; D-19), compressors (D-18; D-20), process piping, tanks and containers (D-19; D-21) and conveying systems (D-20; D-22). These are original practice notes, not material from the Red Seal Program or ESDC. Safety points are principles common to all provinces; a provincial rule is given with its province. For clearances, set points and test pressures, follow the manufacturer's specifications.
Robotics and fans
- Robot cell: lock out the cell and verify each energy source at zero before entering the guarded area; teach mode or a cycle stop is not isolation (sub-task D-15.03).
- Blade types: radial blades shed build-up and resist erosion; curved blades collect deposits; airfoil blades are for clean air (sub-task D-16.01).
- Starting a centrifugal fan: inlet damper closed for the lightest start, then opened gradually (sub-task D-16.01).
- Fan laws: flow varies with speed, pressure with speed², power with speed³: 7.5 hp × (900 ÷ 600)³ = 25.3 hp (sub-task D-16.01).
- Deposits and balance: uneven build-up gives a 1x running-speed peak; clean, then re-balance using a baseline reading and a trial weight (sub-tasks D-16.02, D-16.04).
Pumps
- Pipe strain: casing movement above the manufacturer's limit is corrected at the piping and supports, not by shimming (sub-task D-17.01).
- Impeller tip speed: Formula 11, surface speed = rpm × π × diameter, diameter in feet: 1800 × π × 0.75 ≈ 4240 ft./min. (sub-task D-17.01).
- Cavitation: NPSH available below NPSH required (a plugged strainer, for example); vapour bubbles collapse with a gravel-like noise and erode the suction side of the vanes (sub-task D-17.02).
- Starting: a radial-flow centrifugal pump starts against a closed discharge valve, opened slowly at speed; a positive displacement pump never runs against a closed discharge and needs a relief valve (sub-task D-17.03).
- Rotation: bump-test before coupling; a reversed impeller gives low flow and pressure, not zero (sub-task D-17.04).
Compressors
- Unloader: holds the inlet valves open so the cylinder stops compressing; the check valve stops backflow, drain valves remove condensate (sub-task D-18.01).
- Receiver relief valve: never isolated from the vessel by a block or service valve; test it with the lever while under pressure (sub-tasks D-18.01, D-18.03).
- Filters: lock out and relieve stored pressure before opening (sub-task D-18.03).
- Thermography: an infrared camera shows hot spots (sub-task D-18.02).
Process piping, tanks and containers
- Valves: a gate valve is fully open or closed, since throttling makes the disc chatter and cuts the seats; a globe valve throttles (sub-task D-19.06).
- Schedule: for one nominal size, a higher schedule means a thicker wall and higher pressure capability (sub-task D-19.02).
- Pressure test: water stores little energy, compressed air a lot; supports go in first (sub-task D-19.02).
- Tank volume: Formula 14, height × π × radius²: 8 × π × 3² = 226.2 ft³, × 7.48 = 1692 gal. (sub-task D-19.01).
Conveying systems
- Take-up: gravity or screw type, keeps belt tension so the drive pulley grips (sub-task D-20.01).
- Belt speed: Formula 11 with the pulley diameter in feet: 60 × π × 2 = 377 ft/min (sub-task D-20.01).
- Bucket elevator: buckets on a belt or chain lift bulk material (sub-task D-20.02).
- Chain and sprockets: worn chain and hooked teeth are replaced together (sub-task D-20.03).
- Start-up warning: in Ontario, section 33 of Regulation 851 requires automatic start-up warning devices on conveyor portions not visible from the control station (sub-task D-20.03).
- Skirting: worn skirt rubber is replaced and adjusted to seal on the belt (sub-task D-20.04).
Sample questions (5)
1. Before a millwright enters the guarded work envelope of an automated robotic cell for maintenance, what must be done first?
- Slow the robot to teach-mode speed.
- Lock out the cell and verify zero energy.
- Press cycle stop on the operator panel.
- Ask the operator to pause the program.
Sub-task D-15.03 of the RSOS covers maintaining robotics and automated equipment under site procedures. The cell is locked out and each energy source is verified at zero before anyone enters the guarded area. Teach-mode speed, a cycle stop and a program pause only change the control state, so the robot can still move unexpectedly.
2. An inductive proximity sensor on a robot gripper does not switch when a plastic part is in front of it, although power and wiring are good. What is the cause?
- Inductive sensors do not detect plastic.
- The sensor housing is not properly grounded.
- The part moves too slowly past the sensor.
- The sensor is mounted too close to the arm.
Sub-task D-15.02 of the RSOS covers diagnosing automated equipment, including its sensors. An inductive sensor senses metallic targets, so a plastic part gives no output and a capacitive or photoelectric sensor is needed. A missing ground, a slow target or a nearby arm would not stop a metal target from being sensed.
3. Which type of centrifugal fan blade is the best choice for an airstream carrying dust and sticky material?
- Forward-curved blades.
- Backward-curved blades.
- Flat radial blades.
- Airfoil-section blades.
Sub-task D-16.01 of the RSOS includes identifying types of fan blades and their applications. Radial blades have a simple flat shape that sheds build-up and resists erosion. Forward-curved and backward-curved blades have curved surfaces that collect deposits, and airfoil blades are intended for clean air.
4. A rotary lobe blower delivers a nearly constant volume of air for each revolution. What type of machine is it?
- A positive displacement blower.
- A low-pressure axial-flow fan.
- A high-speed centrifugal blower.
- A high-volume mixed-flow fan.
Sub-task D-16.01 of the RSOS includes identifying types of fan and blower systems. Two meshing lobes trap a fixed volume of air and push it to the discharge, so the machine is positive displacement. Axial, mixed-flow and centrifugal machines are dynamic, and their delivery changes with system pressure.
5. To limit the starting load on a large centrifugal fan, how is the inlet damper set for a first start?
- Fully open, so the motor speeds up faster.
- Fully open, then closed at full speed.
- Half open, then left in that position.
- Closed, then opened slowly at full speed.
Sub-task D-16.01 of the RSOS includes the procedures used to regulate output for fans and blowers. The power drawn by a centrifugal fan rises with flow, so a closed inlet damper gives the lightest start and the damper is opened gradually once the motor is at speed. Starting fully open puts the highest load on the motor and lengthens its acceleration instead of shortening it, closing the damper after the start does nothing for the starting load, and a damper left half open gives neither the lightest start nor full output.