What this topic covers
MWA C, Mechanical Power Transmission, as numbered in the 2017 RSOS: prime movers (task C-9; C-11 in the 2026 RSOS), shafts, bearings and seals (C-10; C-12), couplings, clutches and brakes (C-11; C-13), chain and belt drives (C-12; C-14), gear systems (C-13; C-15) and shaft alignment (C-14; C-16). These are original practice notes, not official material of the Red Seal Program or ESDC. Safety points are principles common to all provinces; a provincial rule is always given with its province. For settings, clearances, torques and temperatures, follow the manufacturer's specifications.
Prime movers
- Bump test: rotation is checked before coupling by a brief start (sub-task C-9.01).
- Soft foot: a foot that moves when its bolt is loosened is measured and shimmed, not pulled down (sub-task C-9.01).
- Slip: synchronous speed minus rotor speed (sub-task C-9.02).
- Overspeed trip: an emergency shutdown device that closes the steam supply of a turbine (sub-task C-9.03).
- Parallel key: snug on the side faces, with top clearance so the hub is not wedged (sub-task C-9.04).
Bearings and seals
- Heating bearings: induction heater, oil bath or bearing oven; never a torch (sub-task C-10.01).
- Designation 62xx: 6 = deep groove ball bearing; from 04 up, last two digits × 5 = bore in mm (08 = 40 mm) (sub-task C-10.02).
- Compressed air: never spin a bearing with an air jet (sub-task C-10.02).
- Packing: offset the joint of each ring from the one before (sub-task C-10.03).
- Mechanical seals: never run dry; fluid at the faces before start-up (sub-task C-10.04).
- Surface speed: Formula 11 of the formula sheet, rpm × π × diameter, diameter in feet for ft./min (sub-task C-10.01).
Couplings, clutches and brakes
- Elastomeric coupling: the element cushions shock and takes up small misalignment (sub-task C-11.01).
- Mounting hubs: heat evenly to the manufacturer's temperature (sub-task C-11.01).
- Diagnosis: thermal imaging shows heat from a safe distance (sub-task C-11.02).
- Brake gap: measured locked out; reset after new pads (sub-tasks C-11.02, C-11.04).
- Dismantling: match (witness) marks first (sub-task C-11.03).
Chain and belt drives
- Half (offset) link: for an odd number of pitches; weaker than a normal link (sub-task C-12.01).
- Worn sprockets: replace the chain and both sprockets together (sub-task C-12.02).
- Belt on groove bottom: the grooves are worn wide (sub-task C-12.02).
- Belt sets: replace as a matched set (sub-task C-12.04).
- Ratios: driver teeth × driver rpm = driven teeth × driven rpm; 24 × 1200 ÷ 400 = 72 teeth (sub-task C-12.03).
Gear systems
- Speed: driven rpm = driver rpm × driver teeth ÷ driven teeth (sub-task C-13.01).
- Helical gears: angled teeth create axial thrust on the bearings (sub-task C-13.01).
- Diametral pitch: number of teeth ÷ pitch diameter (sub-task C-13.01).
- Gear pass frequency: Formula 5, rpm × number of teeth, in cpm; Hz = cpm ÷ 60 (sub-task C-13.02).
- Backlash: hold one gear, rock the other, read the dial indicator (sub-task C-13.02).
- Breather: lets air move so heat does not force oil past the seals (sub-task C-13.03).
Shaft alignment
- Lockout: lock out the driver and verify zero energy before any alignment (sub-task C-14.02).
- Soft foot check: loosen one bolt at a time and watch the indicator (sub-task C-14.01).
- Shims: a few thick, clean, flat shims under the whole foot (sub-task C-14.02).
- Bar sag: zero at the top on a rigid pipe, read at the bottom (sub-task C-14.02).
- Thermal growth: Formula 12, ΔT × length × coefficient; a machine that grows is set low when cold (sub-task C-14.02).
Sample questions (5)
1. Why is a bump test done on a new electric motor before its shaft is coupled to the driven machine?
- To measure the winding resistance.
- To balance the rotor in position.
- To verify the shaft rotation direction.
- To set the final shaft end float.
Sub-task C-9.01 of the RSOS states that “rotation is checked prior to coupling by performing bump test”, so a brief start shows whether the shaft turns the right way for the driven machine. Winding resistance is measured with a meter on a locked-out motor, not by bumping it. Rotor balance and shaft end float are not set by a bump test.
2. A three-phase induction motor turns the wrong way during a bump test. With the motor locked out, what does the electrician do to reverse it?
- Interchange the ground and one line lead.
- Reconnect the stator winding from delta to wye.
- Interchange any two of the three line leads.
- Raise the supply frequency by ten percent.
Interchanging any two of the three line leads reverses the phase sequence and therefore the direction of rotation of a three-phase induction motor; a qualified person does this after lockout and verification of zero energy. A delta to wye change alters the voltage rating and torque, not the direction. Moving the ground to a line terminal is dangerous and does not change rotation, and a higher frequency only raises the speed.
3. A motor foot lifts 0.008 in. when its hold-down bolt is loosened, and the manufacturer allows 0.002 in. What is the condition and the fix?
- Bent shaft; straighten it before aligning.
- Angular misalignment; shim the opposite foot.
- Soft foot; shim under that foot to close the gap.
- Soft foot; tighten the bolt to pull it flat.
Movement at one foot when its bolt is loosened is soft foot, and it is corrected by measuring the gap and shimming that foot, as part of securing and levelling the motor under sub-task C-9.01 of the RSOS. Tightening the bolt pulls the frame down and distorts it, which throws the bearings out of line. A bent shaft shows as runout when the shaft is turned, not as foot movement, and angular misalignment is corrected only after all feet sit flat.
4. Which prime mover turns a rotor directly by directing a high-velocity jet of expanding steam against its blades?
- An impulse steam turbine.
- A reciprocating steam engine.
- A turbocharged diesel engine.
- A three-phase induction motor.
Sub-task C-9.01 of the RSOS lists turbines, steam among them, as prime movers; an impulse steam turbine directs high-velocity steam from fixed nozzles onto the blades of its rotor and turns it directly. A reciprocating steam engine uses steam pressure on a piston and needs a crank to produce rotation. In a turbocharged diesel engine, combustion drives the pistons and the exhaust turbine only boosts the intake air, and an induction motor is turned by a rotating magnetic field.
5. A four-pole 60 Hz induction motor has a synchronous speed of 1800 rpm and a nameplate speed of 1750 rpm. What is the 50 rpm difference called?
- The shaft runout.
- The rotor slip.
- The service factor.
- The gear backlash.
Slip is the difference between synchronous speed and rotor speed; the rotor must lag the rotating field to cut flux and produce torque, so a loaded motor always shows some slip (here 50 ÷ 1800, about 2.8 percent). Runout is shaft wobble, backlash is free play between mating parts, and service factor is a nameplate overload multiplier. Sub-task C-9.02 of the RSOS includes evaluating prime movers against their specifications.